J Refract Surg ; 40(5): e313-e320, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717079

RESUMEN

PURPOSE: To assess the clinical outcomes and safety profiles of patients who underwent immediate sequential bilateral phakic lens surgery. METHODS: This retrospective multicenter study included 254 consecutive patients (508 eyes) who underwent bilateral same-day Implantable Collamer Lens (ICL) (STAAR Surgical) surgery. The authors focused on 1-year postoperative clinical outcomes and adverse events. RESULTS: In the initial cohort, 176 patients (352 eyes) met inclusion criteria. Of these, 335 eyes underwent myopic ICL placement, and 17 eyes received a hyperopic ICL. Notably, 87% of eyes achieved ±0.50 diopters (D) and 95% achieved ±1.00 D of the intended refraction. One year postoperatively, 78% of eyes demonstrated optimal vaulting (250 to 750 µm), with a significant 19% reduction in vaulting observed over the 12 months (P < .001). Only minor adverse events, including early cataract formation (1 case), secondary toric ICL rotation (3 cases), and ICL exchange due to inappropriate vaulting (6 cases), were noted. CONCLUSIONS: The findings corroborate the safety and efficacy of immediate sequential bilateral phakic lens surgery and indicate its potential as a treatment option. The low incidence of minor adverse events further reinforces its favorable safety profile. [J Refract Surg. 2024;40(5):e313-e320.].


Asunto(s)
Hiperopía , Implantación de Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Agudeza Visual/fisiología , Femenino , Adulto , Miopía/cirugía , Miopía/fisiopatología , Refracción Ocular/fisiología , Hiperopía/cirugía , Hiperopía/fisiopatología , Adulto Joven , Resultado del Tratamiento , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios de Seguimiento , Adolescente
2.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717085

RESUMEN

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Asunto(s)
Presión Intraocular , Implantación de Lentes Intraoculares , Facoemulsificación , Agudeza Visual , Humanos , Estudios Prospectivos , Presión Intraocular/fisiología , Masculino , Femenino , Anciano , Agudeza Visual/fisiología , Persona de Mediana Edad , Endotelio Corneal/patología , Recuento de Células , Periodo Posoperatorio , Tomografía de Coherencia Óptica , Hidrodinámica , Cámara Anterior , Periodo Intraoperatorio
3.
Sci Rep ; 14(1): 8386, 2024 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-38600286

RESUMEN

This prospective, non-randomized, comparative study aimed to compare the visual outcomes and patient satisfaction after implantations of three presbyopia-correcting intraocular lenses (IOLs) after myopic refractive surgery. It was conducted from January 2020 to December 2021 in Shanghai Heping Eye Hospital. Patients were divided into three groups based on the type of IOL implanted. The visual acuity, refractive stability, high-order aberrations, objective visual quality, spectacle independence, and visual function index 14 questionnaire scores of the three groups were compared. This study included 78 eyes of 39 patients: 26 eyes with 839MP, 26 eyes with MF30, and 26 eyes with ZXR00. Uncorrected distance visual acuity improved significantly for all three groups. For a pupil diameter of 4.0 mm, the spherical aberrations of the three groups were 0.33 ± 0.16 µ, 0.50 ± 0.08 µ, and 0.39 ± 0.10 µ, respectively. The spectacle independence for distance vision was over 90% in each group; for near vision, it was only 25% for the ZXR00 group. All three types of presbyopia-correcting IOLs improved visual quality in post-LASIK or PRK patients. However, the high incidence of photic phenomena after presbyopia-correcting IOL implantation in patients who have undergone myopic LASIK should not be neglected.


Asunto(s)
Lentes Intraoculares , Miopía , Presbiopía , Humanos , Presbiopía/cirugía , Implantación de Lentes Intraoculares , Satisfacción del Paciente , Estudios Prospectivos , China , Miopía/cirugía , Diseño de Prótesis
4.
Zhonghua Yi Xue Za Zhi ; 104(16): 1391-1396, 2024 Apr 23.
Artículo en Chino | MEDLINE | ID: mdl-38644289

RESUMEN

Objective: To explore the effects of different types of intraocular lens (IOL) implantation on patient's visual quality and function after phacoemulsification. Methods: The clinical data of patients with monocular cataract who underwent phacoemulsification in the Department of Ophthalmology, People's Hospital Affiliated to Shandong First Medical University between December 2021 and May 2023 were retrospectively analyzed. According to the types of IOL, the patients were divided into monofocal group, bifocal group and depth of focus extension group. Three months later, uncorrected distance visual acuity (UCDVA), best corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), best corrected intermediate visual acuity (BCIVA), uncorrected near visual acuity (UCNVA) and best corrected near visual acuity (BCNVA) were detected. Contrast sensitivity and total wavefront aberration were measured by visual function analyzer. Satisfaction with visual quality was evaluated by hospital-made satisfaction questionnaire. Results: A total of 92 patients were included, with 31 males and 61 females, and their age was (61.8±5.2) years. There were 43, 28 and 21 cases in monofocal group, bifocal group and depth of focus extension group, respectively. No statistically significant difference was found in clinical baseline data among the three groups. UCIVA, UCDVA, BCIVA and BCDVA in depth of focus extension group were 1.01±0.13, 0.92±0.18, 1.21±0.19 and 1.20±0.23, respectively, which were higher than those in monofocal group (0.62±0.12, 0.74±0.13, 1.02±0.17, 1.07±0.19, respectively) and bifocal group (0.67±0.15, 0.78±0.14, 1.01±0.16, 1.01±0.18, respectively), while absolute value of spherical equivalent [(-0.42±0.07) D] was lower than that in the other two groups [ (-0.49±0.05) D and (-0.45±0.08) D] (both P<0.05). UCNVA and BCNVA in bifocal group were 0.91±0.18 and 1.25±0.18, which were higher than those in depth of focus extension group (0.63±0.24 and 1.19±0.17) (both P<0.05). There were no significant differences in contrast sensitivity among the three groups under day vision or between monofocal group and bifocal group under night vision (all P>0.05), but the contrast sensitivity was higher in depth of focus extension group under night vision (3.0, 6.0, 12.0 c/d) than other two groups (all P<0.05). The score of ocular discomfort was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). The score of visual interference in bifocal group was lower than that in monofocal group and depth of focus extension group (both P<0.05). The scores of subjective feeling in bifocal group and depth of focus extension group were higher than that in monofocal group (both P<0.05). The reading score was the highest in bifocal group, followed by depth of focus extension group and monofocal group (both P<0.05). There was no significant difference in total low-order aberration among the three groups (P=0.472). The total aberration and higher-order aberration [(0.74±0.35) µm and (0.41±0.12) µm] were the highest in monofocal group, followed by bifocal group [(0.61±0.21) µm and (0.22±0.09) µm] and depth of focus extension group [(0.46±0.13) µm and (0.06±0.09) µm] (all P<0.05). Conclusions: IOL implantation with depth of focus extension can enhance visual range, night vision and contrast sensitivity, and thus effectively improve postoperative visual quality and function in cataract patients. The bifocal IOL can better improve the patient's UCNVA and BCNVA, resulting in high satisfaction with visual quality.


Asunto(s)
Catarata , Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Agudeza Visual , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad de Contraste , Satisfacción del Paciente , Encuestas y Cuestionarios
5.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38644781

RESUMEN

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Asunto(s)
Lentes Intraoculares Multifocales , Presbiopía , Diseño de Prótesis , Refracción Ocular , Agudeza Visual , Humanos , Estudios Prospectivos , Femenino , Masculino , Agudeza Visual/fisiología , Anciano , Persona de Mediana Edad , Presbiopía/fisiopatología , Presbiopía/cirugía , Refracción Ocular/fisiología , Visión Binocular/fisiología , Satisfacción del Paciente , Sensibilidad de Contraste/fisiología , Facoemulsificación , Estudios de Seguimiento , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares
6.
Int Ophthalmol ; 44(1): 198, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662107

RESUMEN

PURPOSE: Cataract surgery in microphthalmic eyes is challenging due to anatomical restraints, hard bulky nucleus. This series aims to evaluate the safety and efficacy of couching of intraocular lens in irido-fundal coloboma with microphthalmos. SETTING: Tertiary care centre in South India. DESIGN: Retrospective non-comparative study in eyes with irido-fundal coloboma, corneal diameter < 7 mm and brown cataract. Visual acuity less than 6/60 in other eye. METHODS: Anterior chamber entry made, zonules broken and lens dislocated into the vitreous cavity in a controlled manner. Baseline Clinico-demographic details, corrected distance visual acuity (CDVA), Intra-ocular pressure (IOP), corneal diameter, axial length, lens status and post-surgery CDVA, IOP and complications recorded and followed up for atleast 6 months. RESULTS: Fifteen eyes of 15 subjects were evaluated with a mean age 49.4 ± 10.9 years. At baseline, mean IOP 14.5 ± 3.8 mmHg, mean axial length 19.3 ± 0.5 mm, mean corneal diameter was 6.5 ± 0.34 mm and CDVA 2 logMAR which improved to 1.5 logMAR at 3 months (p value 0.002). Transient spike in IOP in 33.3% subjects was medically managed with no significant difference in IOP (p > 0.05) at baseline (14.5 ± 3.8 mmHg), 3 months post-surgery (16 ± 2.8 mmHg) and 6 months post-surgery (14.9 ± 2.5 mmHg). One patient underwent re-couching. No other major complications were noted. CONCLUSION: Couching of cataractous lens is an effective and safe method in microphthalmic eyes with irido-fundal coloboma as last resort procedure, where no other surgical procedure may work. It provides an ambulatory gain of visual acuity in previously non-ambulatory subjects. Corneal measurements help in determining the subset of patients where couching offers viable option.


Asunto(s)
Catarata , Coloboma , Microftalmía , Agudeza Visual , Humanos , Estudios Retrospectivos , Femenino , Coloboma/diagnóstico , Coloboma/complicaciones , Coloboma/cirugía , Masculino , Microftalmía/complicaciones , Microftalmía/diagnóstico , Microftalmía/cirugía , Catarata/complicaciones , Catarata/congénito , Catarata/diagnóstico , Persona de Mediana Edad , Adulto , Iris/cirugía , Iris/anomalías , Implantación de Lentes Intraoculares/métodos , Extracción de Catarata/métodos , Cristalino/anomalías , Cristalino/cirugía , Estudios de Seguimiento
7.
Int Ophthalmol ; 44(1): 203, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671195

RESUMEN

PURPOSE: This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. METHODS: This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. RESULTS: All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively (P = 0.37 and P = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian (P = 0.11 and P = 0.22, respectively). CONCLUSIONS: The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. TRIAL REGISTRATION: The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).


Asunto(s)
Extracción de Catarata , Catarata , Lentes Intraoculares Multifocales , Agudeza Visual , Humanos , Masculino , Femenino , Estudios Prospectivos , Catarata/complicaciones , Catarata/fisiopatología , Preescolar , Niño , Extracción de Catarata/métodos , Extracción de Catarata/efectos adversos , Estudios de Seguimiento , Diseño de Prótesis , Migracion de Implante de Lente Artificial/diagnóstico , Migracion de Implante de Lente Artificial/fisiopatología , Migracion de Implante de Lente Artificial/etiología , Migracion de Implante de Lente Artificial/cirugía , Implantación de Lentes Intraoculares/métodos , Lactante
8.
BMC Ophthalmol ; 24(1): 154, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594683

RESUMEN

BACKGROUND: Intraocular lens (IOL) fixation is performed after intraoperative anterior or total vitrectomy. This study aimed to compare the intraoperative and postoperative complications of these two techniques. METHODS: This retrospective study included 235 eyes that underwent intrascleral fixation surgery at our hospital between July 2014 and January 2021. The eyes were classified into the anterior vitrectomy group (A-vit group; 134 eyes) and the pars plana vitrectomy group (PPV group; 101 eyes). The age, preoperative and postoperative best-corrected visual acuity, observation period, preoperative and postoperative intraocular pressure, and the incidence of intraoperative and postoperative complications were assessed. RESULTS: Intrascleral fixation was performed more frequently in the PPV group, and a significant difference was observed between the eyes with a history of vitrectomy and eyes with scleral buckles (p = 0.00041). In terms of the incidence of postoperative complications following intrascleral fixation, the incidence of low intraocular pressure postoperative was higher in the PPV group than that in the A-vit group, and a significant difference was observed between the two groups (p = 0.01). CONCLUSIONS: The visual outcome and complications following intrascleral fixation did not differ according to the extent of vitreous excision.


Asunto(s)
Lentes Intraoculares , Vitrectomía , Humanos , Vitrectomía/efectos adversos , Vitrectomía/métodos , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Agudeza Visual , Esclerótica/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía
9.
BMC Ophthalmol ; 24(1): 172, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627651

RESUMEN

PURPOSE: To assess the efficacy and safety of various intraocular lenses (IOLs), including standard monofocal, bifocal, trifocal, extended depth of focus (EDOF), and enhanced monofocal IOLs, post-cataract surgery through a network meta-analysis. METHODS: A systematic search of PubMed, Cochrane Library, and Web of Science was conducted to identify relevant studies from the past 5 years. Parameters such as binocular visual acuities, spectacle independence, contrast sensitivity (CS), and optical quality were used to evaluate efficacy and safety. Data from the selected studies were analyzed using Review Manager 5.4 and STATA 17.0 software. RESULTS: Twenty-eight Randomized Controlled Trials (RCTs) comprising 2465 subjects were included. Trifocal IOLs exhibited superior uncorrected near visual acuity (UNVA) compared to monofocal IOLs (MD: -0.35; 95% CI: -0.48, -0.22). Both trifocal (AcrySof IQ PanOptix IOLs group MD: -0.13; 95% CI: -0.21, -0.06) and EDOF IOLs (MD: -0.13; 95% CI: -0.17, -0.09) showed better uncorrected intermediate visual acuity (UIVA) than monofocal IOLs. Trifocal IOLs ranked highest in spectacle independence at various distances (AT LISAtri 839MP group: SUCRA 97.5% for distance, 80.7% for intermediate; AcrySof IQ PanOptix group: SUCRA 83.0% for near). CONCLUSIONS: For cataract patients who want to treat presbyopia, trifocal IOLs demonstrated better visual acuity and spectacle independence at near distances. Different types of trifocal IOL characteristics differ. EDOF and enhanced monofocal IOLs have improved visual quality at intermediate distances.Therefore, It is very important to select the appropriate IOLs based on the lens characteristics and patient needs.


Asunto(s)
Catarata , Lentes Intraoculares , Facoemulsificación , Presbiopía , Humanos , Implantación de Lentes Intraoculares , Presbiopía/cirugía , Refracción Ocular , Satisfacción del Paciente , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto
10.
Sci Rep ; 14(1): 8868, 2024 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-38632326

RESUMEN

A retrospective cohort study was conducted to observe the correction effect of Toric intraocular lens (IOL) implantation in cataract eyes with specific types of irregular corneal astigmatism. Thirty-four eyes with either the "asymmetric bow-tie" pattern (Type I) or the "angled bow-tie" pattern (Type II) were included. Corneal topography was assessed using Pentacam HR, and changes in preoperative corneal astigmatism, visual acuity, manifest refraction, and objective visual quality were measured and compared. The average uncorrected distance visual acuity improved significantly from 0.86 ± 0.40 logMAR to 0.22 ± 0.15 logMAR (P < 0.001). Preoperative corneal astigmatism of 2.05 ± 0.90 D was corrected to a postoperative residual astigmatism of 0.78 ± 0.57 D (P < 0.001), with 32% of eyes within 0.50 D. The residual astigmatism prediction errors in Type I and Type II cases were (0.97 ± 0.68 D) and (0.66 ± 0.37 D), respectively (P = 0.100). The mean spherical equivalent prediction error in Type II cases (0.07 ± 0.36 D) was significantly smaller than that in Type I cases (- 0.29 ± 0.52 D) (P = 0.030). This study concludes that Toric IOL implantation effectively corrects specific types of irregular corneal astigmatism in cataract surgery. Eyes with the "angled bow-tie" pattern show higher accuracy in refractive predictions compared to eyes with the "asymmetric bow-tie" pattern.


Asunto(s)
Astigmatismo , Catarata , Enfermedades de la Córnea , Lentes Intraoculares , Facoemulsificación , Humanos , Astigmatismo/cirugía , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Refracción Ocular , Enfermedades de la Córnea/cirugía
11.
J Cataract Refract Surg ; 50(5): 448-452, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38651696

RESUMEN

PURPOSE: To develop an accurate deep learning model to predict postoperative vault of phakic implantable collamer lenses (ICLs). SETTING: Parkhurst NuVision LASIK Eye Surgery, San Antonio, Texas. DESIGN: Retrospective machine learning study. METHODS: 437 eyes of 221 consecutive patients who underwent ICL implantation were included. A neural network was trained on preoperative very high-frequency digital ultrasound images, patient demographics, and postoperative vault. RESULTS: 3059 images from 437 eyes of 221 patients were used to train the algorithm on individual ICL sizes. The 13.7 mm size was excluded because of insufficient data. A mean absolute error of 66.3 µm, 103 µm, and 91.8 µm were achieved with 100%, 99.0%, and 96.6% of predictions within 500 µm for the 12.1 mm, 12.6 mm, and 13.2 mm sizes, respectively. CONCLUSIONS: This deep learning model achieved a high level of accuracy of predicting postoperative ICL vault with the overwhelming majority of predictions successfully within a clinically acceptable margin of vault.


Asunto(s)
Aprendizaje Profundo , Implantación de Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Humanos , Estudios Retrospectivos , Miopía/cirugía , Adulto , Femenino , Masculino , Periodo Posoperatorio , Inteligencia Artificial , Agudeza Visual/fisiología , Persona de Mediana Edad , Adulto Joven , Redes Neurales de la Computación
12.
J Cataract Refract Surg ; 50(5): 498-504, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38651697

RESUMEN

PURPOSE: To compare 3 capsulotomy centration methods. SETTING: Private clinic, Zlin, Czech Republic. DESIGN: Prospective, consecutive case series. METHODS: 180 eyes undergoing cataract surgery had anterior capsule staining with microfiltered 0.4% trypan blue solution before selective laser capsulotomy. The first 60 eyes (Group 1) had mydriatic dilated pupil centered capsulotomies. The next 60 eyes (Group 2) were centered on the trypan blue central landmark (TCL). The final 60 capsulotomies (Group 3) were centered on the patient fixated coaxial Purkinje reflex (CPR). Measurements between key anatomical landmarks and the TCL, CPR capsulotomies, and implanted intraocular lens (IOL) center were made. RESULTS: The TCL, observed in >94% of eyes in the study, coincided with the CPR with a displacement of <0.1 ± 0.1 mm. Group 1 capsulotomies were noticeably decentered on the IOLs by 0.3 ± 0.2 mm. The Group 2 symmetrical IOL relationship was maintained with a decentration of 0.15 ± 0.1 mm. Group 3 had a similar decentration with the IOLs with 0.15 ± 0.1 mm. Verification with IOLMaster 700 data and CALLISTO Eye System showed that the CPR and the TCL were coincident with the measured visual axis. CONCLUSIONS: The clearly visible TCL served as an alternate landmark to the patient fixated CPR, and being on the anterior capsule was not sensitive to tilt. Further patient compliance was not required. Both were superior to dilated pupil centration, to achieve symmetric IOL coverage. This has application for both capsulotomies and capsulorhexes.


Asunto(s)
Capsulorrexis , Colorantes , Facoemulsificación , Azul de Tripano , Humanos , Capsulorrexis/métodos , Estudios Prospectivos , Anciano , Colorantes/administración & dosificación , Implantación de Lentes Intraoculares , Masculino , Femenino , Persona de Mediana Edad , Cápsula Anterior del Cristalino/cirugía , Puntos Anatómicos de Referencia , Cápsula del Cristalino/cirugía , Anciano de 80 o más Años
14.
Klin Monbl Augenheilkd ; 241(4): 369-373, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38653290

RESUMEN

BACKGROUND: Extended depth of focus intraocular lenses (EDOF-IOLs) provide unaided far- and mid-range vision. Refractive IOLs, in contrast to diffractive designs, are associated with a lower depth of focus and absence of dysphotopsia. The aim of this study was to assess spectacle independence for far-range, mid-range, and near-vision activities in patients after implantation of refractive or diffractive EDOF-IOLs using patient-reported outcome measures (PROMs) in a real-world setting. PATIENTS AND METHODS: In 2021 and 2022, all patients in a single center referred for bilateral cataract surgery were assigned to 7 experienced cataract surgeons who either bilaterally implanted only a diffractive EDOF-IOL (Carl Zeiss Meditec AG, AT LARA Jena, Germany, three surgeons) or refractive EDOF-IOL (Johnson & Johnson Vision Inc., Tecnis Eyhance Irvine, California, USA, four surgeons) at the surgeon's discretion, with the aim of bilateral emmetropia. Six months after both cataract surgeries, all patients were contacted by telephone and asked to report their outcomes using a structured questionnaire investigating their spectacle usage for various daily activities and their experience with night glare or halos. Inclusion criteria were a normal postoperative visual potential based on the preoperative examination and completion of the questionnaire regarding postoperative visual experience. RESULTS: Of the patients, 514 underwent bilateral cataract surgery aiming for bilateral emmetropia with the implantation of EDOF-IOLs (422 with Tecnis Eyhance and 92 with AT LARA). A complete questionnaire was obtained from 472 (92%) patients, who were included in the study (393 vs. 79). Comparing Tecnis Eyhance with AT LARA IOL, 54 vs. 57% patients were able to perform most of their daily activities without spectacles, 9 vs. 19% reported not being dependent on spectacles at all, 25 vs. 29% reported using their smartphones without spectacles, 15 vs. 49% patients reported experiencing glares or halos at night, and 1 vs.15% with driving disturbance. Overall, 95 vs. 93% patients described themselves as "satisfied" or "highly satisfied" with their IOL. CONCLUSIONS: With both types of EDOF-IOLs, the majority of patients could perform most of their daily activities without spectacles, except reading, and were highly satisfied with their IOLs. Patients with diffractive Zeiss AT LARA EDOF-IOLs were more likely to accomplish unaided near-range visual tasks; however, they were also at a higher risk of experiencing glares or halos at night.


Asunto(s)
Lentes Intraoculares , Medición de Resultados Informados por el Paciente , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Diseño de Prótesis , Percepción de Profundidad/fisiología , Satisfacción del Paciente/estadística & datos numéricos , Anteojos , Agudeza Visual , Alemania , Implantación de Lentes Intraoculares , Extracción de Catarata
15.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656707

RESUMEN

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Asunto(s)
Segmento Anterior del Ojo , Facoemulsificación , Tomografía de Coherencia Óptica , Humanos , Facoemulsificación/efectos adversos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Anciano , Segmento Anterior del Ojo/diagnóstico por imagen , Lentes Intraoculares/efectos adversos , Persona de Mediana Edad , Agudeza Visual , Anciano de 80 o más Años , Migracion de Implante de Lente Artificial/diagnóstico , Migracion de Implante de Lente Artificial/etiología , Implantación de Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/diagnóstico , Cristalino/diagnóstico por imagen , Estudios Prospectivos
17.
J Refract Surg ; 40(4): e270-e277, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593255

RESUMEN

PURPOSE: To investigate the effect of age on visual outcomes after the bilateral implantation of trifocal intraocular lenses (IOLs). METHODS: A total of 290 patients (580 eyes) who underwent bilateral implantation of a trifocal IOL were enrolled in this retrospective case-control study. Patients were divided into five age groups: 45 to 49, 50 to 54, 55 to 59, 60 to 64, and 65 years and older. Postoperative monocular uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively), uncorrected near visual acuity (UNVA), binocular distance-corrected defocus curve, spectacle dependence for near and distance vision, and patient satisfaction scores were compared among the five groups. RESULTS: The 45 to 49 years group had significantly better mean UDVA (0.02 ± 0.05 logMAR) and UNVA (0.02 ± 0.04 logMAR) than the 65 years and older group (0.06 ± 0.09 and 0.09 ± 0.09 logMAR; P = .029 and P < .001; respectively). However, no significant differences were observed in the mean CDVA among the groups. Binocular visual performance of the 45 to 49 years group was better than that of the 65 years and older age group at defocuses of +1.00, +0.50, -1.00, and -3.00 D. No significant differences were observed in spectacle dependence for near and distance vision or in patient satisfaction scores among the five groups. CONCLUSIONS: Bilateral implantation of trifocal IOLs can provide excellent near and distance vision in both young and older patients. However, UDVA and UNVA revealed considerably worse results in the older group, although no significant difference was observed in CDVA and postoperative refractive errors by age. [J Refract Surg. 2024;40(4):e270-e277.].


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Anciano , Persona de Mediana Edad , Refracción Ocular , Implantación de Lentes Intraoculares , Anteojos , Estudios Retrospectivos , Estudios de Casos y Controles , Visión Binocular , Satisfacción del Paciente , Diseño de Prótesis
18.
J Refract Surg ; 40(4): e199-e207, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593258

RESUMEN

PURPOSE: To investigate the efficacy of incorporating Generative Adversarial Network (GAN) and synthetic images in enhancing the performance of a convolutional neural network (CNN) for automated estimation of Implantable Collamer Lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT). METHODS: This study was a retrospective evaluation using synthetic data and real patient images in a deep learning framework. Synthetic ICL AS-OCT scans were generated using GANs and a secondary image editing algorithm, creating approximately 100,000 synthetic images. These were used alongside real patient scans to train a CNN for estimating ICL vault distance. The model's performance was evaluated using statistical metrics such as mean absolute percentage error (MAPE), mean absolute error (MAE), root mean squared error (RMSE), and coefficient of determination (R2) for the estimation of ICL vault distance. RESULTS: The study analyzed 4,557 AS-OCT B-scans from 138 eyes of 103 patients for training. An independent, retrospectively collected dataset of 2,454 AS-OCT images from 88 eyes of 56 patients, used prospectively for evaluation, served as the test set. When trained solely on real images, the CNN achieved a MAPE of 15.31%, MAE of 44.68 µm, and RMSE of 63.3 µm. However, with the inclusion of GAN-generated and algorithmically edited synthetic images, the performance significantly improved, achieving a MAPE of 8.09%, MAE of 24.83 µm, and RMSE of 32.26 µm. The R2 value was +0.98, indicating a strong positive correlation between actual and predicted ICL vault distances (P < .01). No statistically significant difference was observed between measured and predicted vault values (P = .58). CONCLUSIONS: The integration of GAN-generated and edited synthetic images substantially enhanced ICL vault estimation, demonstrating the efficacy of GANs and synthetic data in enhancing OCT image analysis accuracy. This model not only shows potential for assisting postoperative ICL evaluations, but also for improving OCT automation when data paucity is an issue. [J Refract Surg. 2024;40(4):e199-e207.].


Asunto(s)
Cristalino , Miopía , Lentes Intraoculares Fáquicas , Humanos , Tomografía de Coherencia Óptica/métodos , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Miopía/cirugía
19.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593262

RESUMEN

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Asunto(s)
Queratocono , Lentes Intraoculares , Facoemulsificación , Humanos , Queratocono/diagnóstico , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Facoemulsificación/métodos , Óptica y Fotónica , Refracción Ocular , Biometría/métodos
20.
BMC Ophthalmol ; 24(1): 198, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671381

RESUMEN

BACKGROUND: Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). METHODS: This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. RESULTS: There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). CONCLUSIONS: Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. TRIAL REGISTRATION: This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).


Asunto(s)
Lentes Intraoculares , Agudeza Visual , Humanos , Estudios Prospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Anciano , Persona de Mediana Edad , Facoemulsificación , Refracción Ocular/fisiología , Implantación de Lentes Intraoculares , Diseño de Prótesis , Periodo Posoperatorio , Seudofaquia/fisiopatología , Óptica y Fotónica
SELECCIÓN DE REFERENCIAS